| Revit 2016 API |
| BuiltInFailures..::..MEPFabricationFailures Members |
| BuiltInFailures..::..MEPFabricationFailures Class Properties See Also |
Provides a container of all Revit built-in FailureDefinitionId instances.
The BuiltInFailures..::..MEPFabricationFailures type exposes the following members.
Properties
| Name | Description | |
|---|---|---|
| CannotConvertFlexPipeToPart |
Cannot convert flex pipe to fabrication part.
| |
| CannotMatchFabricationHangerSizeToHost |
The hanger cannot be re-sized to match the re-sized host.
| |
| FabDbChangeConn |
Fabrication Database changes altered connectivity
| |
| FabDbOpenJobConn |
Fabrication job imported had bad connectivity
| |
| FabricationConfigurationCorrupted |
It looks that the Fabrication Configuration %1!s! was corrupted, please check it at %2!s!.
| |
| FabricationHangerCannotBeSloped |
A hanger cannot be sloped or placed on a sloped element.
| |
| FabricationHangerHostNotFound |
The hanger will disconnect because we can't find the suitable host.
| |
| FabricationHangerNotConnectToHost |
Fabrication Hanger didn't connect to the %s host.
| |
| FabricationHangerOutOfHost |
The hanger is out of its host and will be disconnected.
| |
| FabricationHangerSizeNotMatch |
The hanger size does not match the size of the host, so it can not be connected.
| |
| FabricationPartCannotBeMirrored | ||
| FabricationPartHasInvalidGeometry |
The fabrication part either has no material or has badly configured dimensions, resulting in bad geometry.
| |
| FabricationPartInvalidConnection |
Fabrication Part connection invalid and could not be automatically coupled.
| |
| FabricationPartNoPartTypeFound |
There are no fabrication part types found for the current Configuration and Service. Please select settings and reload the service to create the fabrication part types.
| |
| FabricationRodsConnectionChangedWarning |
The structural component that the hanger is attached to has changed to a different element.
| |
| FabricationRodsDisconnectedError |
The hanger rod was disconnected because there is no structural component above.
| |
| FabricationRodsDisconnectedWarning |
The hanger rod was disconnected because there is no structural component above.
| |
| NoStructuralHostToAttachWarning |
There is no structural component to attach the hanger rod to.
| |
| PlaceCutinFittingFailed |
Failed to insert part.
| |
| SizeNotAvailableInFabricationService |
Sizes:%1!s! in system %2!s! are not available in fabrication service:%3!s!, All available sizes are:\n%4!s!.
|