Provides a container of all Revit built-in FailureDefinitionId instances.
The BuiltInFailures..::..MEPFabricationFailures type exposes the following members.
Properties
| Name | Description | |
|---|---|---|
| CannotConvertFlexPipeToPart |
Cannot convert flex pipe to fabrication part.
| |
| CannotMatchFabricationHangerSizeToHost |
The hanger cannot be re-sized to match the re-sized host.
| |
| FabDbChangeConn |
Fabrication Database changes altered connectivity
| |
| FabDbOpenJobConn |
Fabrication job imported had bad connectivity
| |
| FabricationConfigurationCorrupted |
It looks that the Fabrication Configuration %1!s! was corrupted, please check it at %2!s!.
| |
| FabricationHangerCannotBeSloped |
A hanger cannot be sloped or placed on a sloped element.
| |
| FabricationHangerHostNotFound |
The hanger will disconnect because we can't find the suitable host.
| |
| FabricationHangerNotConnectToHost |
Fabrication Hanger didn't connect to the %s host.
| |
| FabricationHangerOutOfHost |
The hanger is out of its host and will be disconnected.
| |
| FabricationHangerSizeNotMatch |
The hanger size does not match the size of the host, so it can not be connected.
| |
| FabricationOutOfSizeCondition |
The fabrication part size is not within the correct size range for the service button condition.
| |
| FabricationOverSizedCheck |
Fabrication part is too large to fit on the sheet metal. Replace the part with multiple smaller parts, or notify the CAM operator.
| |
| FabricationPartCannotBeMirrored | ||
| FabricationPartCannotChangeTypeError |
The selected fitting(s) cannot successfully change the type. You must disconnect the connections on the fitting(s) and try again.
| |
| FabricationPartCannotChangeTypeWarning |
The selected fitting(s) cannot maintain connections to existing fabrication parts due to size, direction or angle differences. You must manually reconnect the open connections.
| |
| FabricationPartFitFailure |
Fabrication Part Fitting Failed to Fit
| |
| FabricationPartHasInvalidGeometry |
The fabrication part either has no material or has badly configured dimensions, resulting in bad geometry.
| |
| FabricationPartInvalidConnection |
Fabrication Part connection invalid and could not be automatically coupled.
| |
| FabricationPartInvalidSpecification |
The part specification is invalid.
| |
| FabricationPartNoPartTypeFound |
There are no fabrication part types found for the current Configuration and Service. Please select settings and reload the service to create the fabrication part types.
| |
| FabricationPartNotAttachedToStraight |
The part must be attached to straight.
| |
| FabricationPartOptimizeInvalidConnection |
No available couplings to connect standard lengths for this instance of straight.
| |
| FabricationRodDetachFromHangerError |
The rod need to be detached from hanger.
| |
| FabricationRodsConnectionChangedWarning |
The structural component that the hanger is attached to has changed to a different element.
| |
| FabricationRodsDisconnectedError |
The hanger rod was disconnected because there is no structural component above.
| |
| FabricationRodsDisconnectedWarning |
The hanger rod was disconnected because there is no structural component above.
| |
| FabricationServiceMismatch |
Attempting to connect fabrication parts from different services.
| |
| FabricationStraigtLengthOversized |
Fabrication straight exceeds the standard length. Use the Optimize Length command to adjust the length.
| |
| FixedFabricationPartNotChangeLength |
Failed to change length of fixed part.
| |
| GroupedFabricationPartNotReposition |
Failed to reposition part.
| |
| HangerProfileNotMatchWithHost |
The defined hanger profile does not match with the host.
| |
| HangerWidthOutOfRange |
The hanger width is too large to show.
| |
| InvalidConnectionsHaveBeenDisconnected |
Invalid connections have been disconnected. Please reconnect them manually or use different fittings.
| |
| InvalidSelectionThereCannotBeOpenConnectors |
Invalid selection there cannot be any open connectors for the design to fabrication part tool.
| |
| NoStructuralHostToAttachWarning |
There is no structural component to attach the hanger rod to.
| |
| NotAllPartsWereConvertedUnsuportedFittingOffsets |
Not all parts were converted. Eccentric transitions and taps that have offsets from the center line are unsupported and cannot be converted.
| |
| PinnedFabricationPartNotChangeExtension |
Failed to change extension of part.
| |
| PinnedFabricationPartNotReposition |
Failed to reposition part.
| |
| PlaceCutinFittingFailed |
Failed to insert part.
| |
| SizeNotAvailableInFabricationService |
Sizes:%1!s! in system %2!s! are not available in fabrication service:%3!s!, All available sizes are:\n%4!s!.
| |
| UneditableFabricationPartNotReposition |
Failed to reposition part.
|