The BuiltInFailuresAnalyticalModelFailures type exposes the following members.
| Name | Description | |
|---|---|---|
| AdjustCurveTooShort | AdjustCurve is too short. | |
| AdjustEdgeTooShort | AdjustEdge is too short. | |
| AdjustEdgeTooShortErr | AdjustEdge is too short - continuable error version. | |
| AdjustEdgeTooShortWarn | AdjustEdge is too short. | |
| AnalyticalBeamSlabWarning | Beam and Slab Analytical Models do not have the same Analytical Projection Plane. | |
| AnalyticalCurvedPanelNotValid | Analytical Curved Panel is not valid. | |
| AnalyticalDiscrepancyWarning | Distance between Analytical and Physical Models of Structural Element is beyond tolerance of [Value] | |
| AnalyticalElementsInvalidAfterUpgrade | One or several analytical elements have become invalid during the upgrade process and will be deleted. | |
| AnalyticalGapWarning | Detected physical connection between Structural Elements, but did not detect Analytical intersection. | |
| AnalyticalLinkJoinedNodes | Analitycal Link is invalid. Reference nodes have been joined. | |
| AnalyticalLinkNotConnected | Analytical Link has lost one or more references. | |
| AnalyticalMemberInstability | Possible Member Instability, based on Release Conditions | |
| AnalyticalModelInstability | Possible Model Instability | |
| AnalyticalModelIsIncorrect | Analytical Model is not created for the structural element. | |
| AnalyticalPanelNotPlanar | Analytical Panel is not planar. | |
| AnalyticalPanelNotVisible | Analytical Panel is not visible in the current view. | |
| AnalyticalPhysicalCheckDone | Analytical / Physical Model Consistency check is complete. | |
| AnalyticalSupportCycleWarning | Circular support chain detected | |
| AnalyticalSurfaceCannotMove | Cannot move analytical surface. | |
| AnalyticalSurfaceCannotMoveByConnector | Cannot move analytical surface because it will disconnect the analytical nodes. | |
| AnalyticalTopBottomPlanesReversed | Analytical Top Projection Plane is partially or completely below Analytical Bottom Projection Plane. Please reset top and/or bottom planes to valid values. | |
| AutoDetectIgnoreLeaderWarning | Analytical Model for Structural Element has reset to its default location. | |
| BoundaryLinesIntersect | Boundary lines intersect. | |
| CannotCreateAnalyticalGeometry | Cannot construct Analytical Geometry. | |
| CannotKeepAnalyticalAdjustment | Analytical model Adjustment distance exceeds current Adjustment Snapping Distance. To adjust snap settings, go to the Structural Settings Dialog. | |
| CannotMakeAnalyticalGeometry | Cannot construct Analytical Geometry. | |
| CannotSlantAnalyticalWallError | Cannot slant a wall with an Analytical Model. Please disable the Analytical Model first. | |
| ContextualAnalyticalModelModeNotEnabled | Contextual Analytical Model not enabled. File open was canceled. | |
| HighestAssociatedLevelBelowLowestAssociatedLevel | The Highest Associated Level is set below the Lowest Associated Level | |
| LoadsMayBeNotUpToDate | Reactions defined as Internal Load (Is Reaction) may no longer be valid since the analytical model has changed. | |
| LowestAssociatedLevelAboveHighestAssociatedLevel | The Lowest Associated Level is set above the Highest Associated Level | |
| ProjectionPlaneInvalidWall | Projection plane becomes invalid for this wall. | |
| ProjectionPlanesNotIntersect | Can't project Analytical Model. Planes do not intersect each other. | |
| ProjectionPlanesParallel | Can't project Analytical Model. Two or more projection planes are parallel. | |
| StructAnalyticalErrorProjection | Can't project Analytical Model to Analytical Projection Surface | |
| StructuralElementMayNotBeSupported | Structural Element may not be supported -- verify support for Element. | |
| StructWallAnalyticalErrorAlign | Can't align Analytical Model with joined Walls. | |
| StructWallAnalyticalErrorConversion | Can't convert Edges to Analytical Model curves. | |
| SupportCheckDone | Member support check is complete. No unsupported elements detected. | |
| UnableToUpgradeAnalyticalElementGeometry | Unable to upgrade analytical element with incorrect geometry. To keep the elements, open Revit 2022 and correct the elements. | |
| WallAMLostAdjustmentReference | Wall Analytical Model has lost its adjustment reference. |