Revit 2025.3 API
Conduit |
Constructs an object that stores the basic size information for conduit.
Namespace: Autodesk.Revit.DB.Electrical
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.3.0.0 (25.3.0.0)
Syntax
public ConduitSize( double nominalDiameter, double innerDiameter, double outerDiameter, double bendRadius, bool usedInSizeLists, bool usedInSizing )
Public Sub New ( nominalDiameter As Double, innerDiameter As Double, outerDiameter As Double, bendRadius As Double, usedInSizeLists As Boolean, usedInSizing As Boolean )
public: ConduitSize( double nominalDiameter, double innerDiameter, double outerDiameter, double bendRadius, bool usedInSizeLists, bool usedInSizing )
new : nominalDiameter : float * innerDiameter : float * outerDiameter : float * bendRadius : float * usedInSizeLists : bool * usedInSizing : bool -> ConduitSize
Parameters
- nominalDiameter Double
- Nominal diameter. The value should be a valid, positive Revit length.
- innerDiameter Double
- Inner diameter. The value should be a valid, positive Revit length.
- outerDiameter Double
- Outer diameter. The value should be a valid, positive Revit length.
- bendRadius Double
- Minimum bend radius. The value should be a valid, positive Revit length.
- usedInSizeLists Boolean
- Whether it is used in size lists.
- usedInSizing Boolean
- Whether is used in sizing.

Exception | Condition |
---|---|
ArgumentOutOfRangeException | The given value for nominalDiameter must be greater than 0 and no more than 30000 feet. -or- The given value for innerDiameter must be greater than 0 and no more than 30000 feet. -or- The given value for outerDiameter must be greater than 0 and no more than 30000 feet. -or- The given value for bendRadius must be greater than 0 and no more than 30000 feet. |
See Also