Creates a new flexible duct into the document, using a point array and flexible duct type.
Namespace: Autodesk.Revit.DB.Mechanical
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)
Syntax
public static FlexDuct Create( Document document, ElementId systemTypeId, ElementId ductTypeId, ElementId levelId, IList<XYZ> points )
Public Shared Function Create ( document As Document, systemTypeId As ElementId, ductTypeId As ElementId, levelId As ElementId, points As IList(Of XYZ) ) As FlexDuct
public: static FlexDuct^ Create( Document^ document, ElementId^ systemTypeId, ElementId^ ductTypeId, ElementId^ levelId, IList<XYZ^>^ points )
static member Create : document : Document * systemTypeId : ElementId * ductTypeId : ElementId * levelId : ElementId * points : IList<XYZ> -> FlexDuct
Parameters
- document Document
- The document.
- systemTypeId ElementId
- The id of the HVAC system type.
- ductTypeId ElementId
- The id of the flexible duct.
- levelId ElementId
- The level id for the flexible duct.
- points IListXYZ
- The point array indicating the path of the flexible duct, including the end point.
Return Value
FlexDuctIf creation was successful then a new flexible duct is returned, otherwise an exception with failure information will be thrown.
| Exception | Condition |
|---|---|
| ArgumentException | The systemTypeId is not valid HVAC system type. -or- The type ductTypeId is not valid flexible duct type. -or- The ElementId levelId is not a Level. -or- The valid number of points is less than two. In order to create a flex curve, at least two points are required. Note the duplicate points don't take into account. |
| ArgumentNullException | A non-optional argument was null |
See Also