PanelScheduleView.SetSpareCurrentValue Method

PanelScheduleViewSetSpareCurrentValue Method

Sets the value of the apparent current parameter for a spare

Namespace: Autodesk.Revit.DB.Electrical
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)
Syntax
public void SetSpareCurrentValue(
	int row,
	int column,
	ElementId idCurrentParameter,
	double value
)
Public Sub SetSpareCurrentValue ( 
	row As Integer,
	column As Integer,
	idCurrentParameter As ElementId,
	value As Double
)
public:
void SetSpareCurrentValue(
	int row, 
	int column, 
	ElementId^ idCurrentParameter, 
	double value
)
member SetSpareCurrentValue : 
        row : int * 
        column : int * 
        idCurrentParameter : ElementId * 
        value : float -> unit 

Parameters

row  Int32
A row where the valid spare is
column  Int32
A column where the valid spare is
idCurrentParameter  ElementId
One of 4 valid current parameters: RBS_ELEC_APPARENT_CURRENT_PARAM, RBS_ELEC_APPARENT_CURRENT_PHASEA_PARAM, RBS_ELEC_APPARENT_CURRENT_PHASEB_PARAM, RBS_ELEC_APPARENT_CURRENT_PHASEC_PARAM
value  Double
The value of the spare's current for the given parameter
Exceptions
ExceptionCondition
ArgumentException The current parameter id is not valid.
ArgumentNullException A non-optional argument was null
ArgumentOutOfRangeException The given value for value must be non-negative.
ArgumentsInconsistentException The row column combination does not represent a valid spare.