BuiltInFailures.MEPCalculationFailures Members

Provides a container of all Revit built-in FailureDefinitionId instances.

The BuiltInFailures..::..MEPCalculationFailures type exposes the following members.

Properties

  NameDescription
Public propertyStatic memberAtLeastOneEquipmentOnDuty
There should be at least one equipment on duty.
Public propertyStatic memberClassificationNotSetInFamily
A calculation did not complete because the Classification parameter in the Mechanical Equipment family is not set.
Public propertyStatic memberDemandFlowAndPressureLossNotSetInLossFamily
A calculation did not complete because the pressure loss value for element is not set. Select the element and enter a value for the Pressure Loss.
Public propertyStatic memberDemandFlowNotSetInLossFamily
A calculation did not complete because the Demand Flow for the element is not set.
Public propertyStatic memberDuctFittingAndAccessoryPressureDropCalculatorNotAvailable
Duct Fitting/Accessory Pressure Drop Calculator Not Available: [Calculator Name]
Public propertyStatic memberDuctPressureDropCalculatorNotAvailable
Duct Pressure Drop Calculator Not Available: [Calculator Name]
Public propertyStatic memberExtraPumpSet
More than one parallel pump set defined for the same loop. Verify the flow distribution and delete the extra set, if desired.
Public propertyStatic memberFlowAndPressureCalculationMethodHasBeenImproved
During upgrade pressure drop calculations for hydronic piping systems using Simplified Colebrook or Custom Calculation methods have been recalculated using the Colebrook equation.
Public propertyStatic memberHydraulicSeparationAmbiguity
Unable to hydraulically separate until the system has flow.
Public propertyStatic memberHydraulicSeparationOfOneSystem
Unable to hydraulically separate the loop when both supply and return are assigned to the same system. Try again with both start and end selected.
Public propertyStatic memberInvalidNumberOfMechanicalEquipmentOnDuty
The number of on duty equipment must be less than or equal to the number of available equipments.
Public propertyStatic memberLoopSeparationNotCompleted
The loop separation is not completed yet. Only one side of the secondary/tertiary loop is separated. In order to correctly calculate the flow and pressure loss, please check and separate the other end of the loop.
Public propertyStatic memberMechanicalEquipmentSetBeingDeleted
The mechanical equipment set was deleted because it no longer contained any members.
Public propertyStatic memberNetwork_ElementNodeIsNotPartOfNetwork
The calculation could not be executed as configured. At least one of the elements in this network uses a node that is not part of the network.
Public propertyStatic memberNetwork_NodePropertyNotSet
The calculation could not be executed as configured. Specify a constraint property set for the following input or output node(s).
Public propertyStatic memberNetwork_NoInputNode
The calculation could not be executed as configured. Select an input node before analyzing this network.
Public propertyStatic memberNetwork_NoOutputNode
The calculation could not be executed as configured. Select an output node before analyzing this network.
Public propertyStatic memberNetwork_NoPressureConstraint
The calculation could not be executed as configured. Each network requires at least 1 pressure constraint. Specify the pressure constraint.
Public propertyStatic memberNetwork_NotEnoughElements
The calculation could not be executed as configured. Specify at least 3 elements before analyzing this network.
Public propertyStatic memberNetwork_NotEnoughNodes
The calculation could not be executed as configured. Specify at least 4 elements before analyzing this network.
Public propertyStatic memberNetwork_NotFullyConnected
The network is not well connected. Some elements may have unexpected flow and pressure loss values.
Public propertyStatic memberNetwork_OverConstrained
The calculation could not be executed as configured. The Pressure and Flow Rate combined constraint requires at least 2 other pressure or flow constraints. Specify additional constraints.
Public propertyStatic memberNetworkCanNotDeterminCriticalPath
The calculation has completed, but there may be an error in determining the critical path. Verify that demand flow is specified for all required elements.
Public propertyStatic memberNetworkDefaultToPressure
The network uses the default pressure.
Public propertyStatic memberNetworkDefaultToReynolds
The network uses the default Reynolds number.
Public propertyStatic memberNetworkEnergyEquationNotConverge
The energy calculation could not be performed.
Public propertyStatic memberNetworkErrorCalculatingPressure
The pressure calculation could not be performed.
Public propertyStatic memberNetworkErrorElementWithDownUpStreamNode
The network needs an input or output element to perform the calculation.
Public propertyStatic memberNetworkErrorExtractCurveData
The calculation could not be performed. Verify the pump curve data.
Public propertyStatic memberNetworkErrorModelTooBig
The size of the network exceeds the current limit for flow/pressure analysis. In the Mechanical Settings dialog, under Pipe Settings - Calculation, disable the option to Use analysis for closed loop hydronic networks.
Public propertyStatic memberNetworkErrorOverConstrained
The calculation could not be performed due to overconstrained flow condition in the network.
Public propertyStatic memberNetworkExtraPumpOutsideSet
Flow calculations do not calculate this pump together with the other pumps as one equipment set. Verify the flow distribution and add the pump to the equipment set, if desired.
Public propertyStatic memberNetworkInconsistentDemandFlow
The specified flow on this equipment is inconsistent with the other equipment in this branch. The branch flow is calculated based on the maximum specified value.
Public propertyStatic memberNetworkMinorLossNotConverge
The minor loss calculation could not be performed.
Public propertyStatic memberNetworkPressureNotConverge
The calculation could not be performed. Verify the pressure on the input element.
Public propertyStatic memberNetworkUnderConstrained
The network is under constrained. You may specify the design flow value in the missing branches, or cap the open ends.
Public propertyStatic memberPipeConnectorsAreNotLined
A calculation did not complete because the connectors used by this family to connect to the network are not linked.
Public propertyStatic memberPipeFittingAndAccessoryPressureDropCalculatorNotAvailable
Pipe Fitting/Accessory Pressure Drop Calculator Not Available: [Calculator Name]
Public propertyStatic memberPipePressureDropCalculatorNotAvailable
Pipe Pressure Drop Calculator Not Available: [Calculator Name]
Public propertyStatic memberPlumbingFlowCalculatorNotAvailable
Plumbing Flow Calculator Not Available: [Calculator Name]
Public propertyStatic memberPressureLossNotSetInLossFamily
A calculation did not complete because the pressure loss value for the source equipment is not set for the network.
Public propertyStatic memberPumpPressureNotComputed
The calculated pressure drop of this pump is not computed because the critical path is not a closed loop. Check to see if there are other pumps intended for use within a secondary/tertiary loop. Use the Add Separation tool to define the secondary/tertiary loop.
Public propertyStatic memberSeparationNotAtJunction
This hydraulic loop is not separated at any junction. Use the Remove Separation tool to clean up undesired hydraulic separations.
Public propertyStatic memberSeparationWithOddJunction
Hydraulic separation requires an even number of junctions on the header pipe for accurate calculations. Add or remove junctions to complete the separation.