Places a tag on an element or subelement.
Namespace: Autodesk.Revit.DB
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.3.0.0 (25.3.0.0)
Syntax
public static IndependentTag Create( Document document, ElementId symId, ElementId ownerDBViewId, Reference referenceToTag, bool addLeader, TagOrientation tagOrientation, XYZ pnt )
Public Shared Function Create ( document As Document, symId As ElementId, ownerDBViewId As ElementId, referenceToTag As Reference, addLeader As Boolean, tagOrientation As TagOrientation, pnt As XYZ ) As IndependentTag
public: static IndependentTag^ Create( Document^ document, ElementId^ symId, ElementId^ ownerDBViewId, Reference^ referenceToTag, bool addLeader, TagOrientation tagOrientation, XYZ^ pnt )
static member Create : document : Document * symId : ElementId * ownerDBViewId : ElementId * referenceToTag : Reference * addLeader : bool * tagOrientation : TagOrientation * pnt : XYZ -> IndependentTag
Parameters
- document Document
- The document to which the tag will be added.
- symId ElementId
- The id for the FamilySymbol which determines the tag's type.
- ownerDBViewId ElementId
- The view in which the tag will be visible.
- referenceToTag Reference
- The host reference of the tag. The reference can be to an element or subelement in a local or linked document.
- addLeader Boolean
- When true, the tag will be created with a straight leader with an attached end.
- tagOrientation TagOrientation
- The orientation of the tag's head.
- pnt XYZ
- For tags without leaders, this point is the position of the tag head. For tags with leaders, this point is the end point of the leader, and a leader of default length will be created from this point to the tag head.
Return Value
IndependentTagIf successful the new tag is returned.
| Exception | Condition |
|---|---|
| ArgumentException | The ElementId ownerDBViewId does not correspond to a View. -or- The ElementId ownerDBViewId is a view template. -or- The ElementId ownerDBViewId is a perspective view. -or- The 3D view ownerDBViewId is not locked. -or- The ElementId symId does not correspond to a FamilySymbol. -or- The reference can not be tagged. |
| ArgumentNullException | A non-optional argument was null |
| ArgumentOutOfRangeException | A value passed for an enumeration argument is not a member of that enumeration |
| InternalException | Tag creation failed. |
| ModificationForbiddenException | The document is in failure mode: an operation has failed, and Revit requires the user to either cancel the operation or fix the problem (usually by deleting certain elements). -or- The document is being loaded, or is in the midst of another sensitive process. |
| ModificationOutsideTransactionException | The document has no open transaction. |
See Also